Click the image to see details. |
Outlines | Our contacting vibrometer(PU-51N) can measure the vibration of the bearing base by being set in the bearing base and the casing of turning machines all the time, and the monitor which is set in the instrumental room can control and record the abnormal value. | |
Features |
・Easy to be set in the bearing base because it is conecting type ・Can be used in danger area such as petrochemical plants (The pressure-resistant and explosion-protected structure) | |
Purpose | General Vibrometer | It is the general type, which can measure from 10 to 250Hz. It can measure general turning machines. |
Specs | The sort of Explosion-protected Structure | The pressure-resistant and explosion-protected open-air water-resistant structure |
Grade | UBT4 | |
Attested Number | No.C15647 | |
Measurable Amplitude | 0〜1000μm | |
Measurable Frequency | 10〜250Hz | |
Tolerant Acceleration | 100m/sec2 | |
Output Impedance | 100Ω | |
Cable | Shield pair cable CVVS-2mm2, max 1km | |
Surrounding Temperature | -20℃〜80℃ | |
Weight | Approx. 2.3s | |
Size | H×W×D: 107×150×120mm (The Fixing Hole Interval: 130mm) | |
Material | AL | |
Screws to connect Electric Wire Pipe | The pressure-resistant packing appliance Diameter of the cable which suit protective tube G 3/4: φ10〜12 | |
Order | PU-51N |